Quality is life, service is the tenet
發(fā)布時(shí)間: 2024-08-13
產(chǎn)品型號(hào): GDAT-A
廠商性質(zhì): 生產(chǎn)廠家
所 在 地: 北京市海淀區(qū)上地科技園上地十街1號(hào)
產(chǎn)品特點(diǎn): 介電常數(shù)與介質(zhì)損耗測(cè)定儀工作特性 1.Q值測(cè)量 a.Q值測(cè)量范圍:2~1023; b.Q值量程分檔:30、100、300、1000、自動(dòng)換檔或手動(dòng)換檔;c.標(biāo)稱(chēng)誤差頻率范圍25kHz~10MHz100kHz~10MHz固有誤差≤5%±滿度值的2%≤5%±滿度值的2%工作誤差≤7%±滿度值的2%≤7%±滿度值的2%頻率范圍10MHz~60MHz
介電常數(shù)與介質(zhì)損耗測(cè)定儀工作特性
1.Q值測(cè)量
a.Q值測(cè)量范圍:2~1023;
b.Q值量程分檔:30、100、300、1000、自動(dòng)換檔或手動(dòng)換檔;
c.標(biāo)稱(chēng)誤差
A | C | |
頻率范圍 | 25kHz~10MHz | 100kHz~10MHz |
固有誤差 | ≤5%±滿度值的2% | ≤5%±滿度值的2% |
工作誤差 | ≤7%±滿度值的2% | ≤7%±滿度值的2% |
頻率范圍 | 10MHz~60MHz | 10MHz~160MHz |
固有誤差 | ≤6%±滿度值的2% | ≤6%±滿度值的2% |
工作誤差 | ≤8%±滿度值的2% | ≤8%±滿度值的2% |
2.電感測(cè)量范圍
A | C |
14.5nH~8.14H | 4.5nH~140mH |
3.電容測(cè)量
A | C | |
直接測(cè)量范圍 | 1~460p | 1~205p |
主電容調(diào)節(jié)范圍 | 40~500pF | 18~220pF |
準(zhǔn)確度 | 150pF以下±1.5pF; 150pF以上±1% | 150pF以下±1.5pF 150pF以上±1% |
注:大于直接測(cè)量范圍的電容測(cè)量見(jiàn)使用方法。
4.信號(hào)源頻率覆蓋范圍
| A | C |
頻率范圍 | 10kHz~60MHz | 0.1~160MHz |
CH1 | 10~99.9999kHz | 0.1~0.999999MHz |
CH2 | 100~999.999kHz | 1~9.99999MHz |
CH3 | 1~9.99999MHz | 10~99.9999MHz |
CH4 | 10~60MHz | 100~160MHz |
頻率指示誤差 | 3×10-5±1個(gè)字 |
5.Q合格指示預(yù)置功能:預(yù)置范圍:5~1000
6.Q表正常工作條件
a. 環(huán)境溫度:0℃~+40℃;
b.相對(duì)濕度:<80%;
c.電源:220V±22V,50Hz±2.5Hz。
7.其他
a.消耗功率:約25W;
b.凈重:約7kg;
c.外型尺寸:(寬×高×深)mm:380×132×280。
特點(diǎn):
◎ 本公司創(chuàng)新的自動(dòng)Q值保持技術(shù),使測(cè)Q分辨率至0.1Q,使tanδ分辨率至0.00005 。
◎ 能對(duì)固體絕緣材料在10kHz~120MHz介質(zhì)損耗角(tanδ)和介電常數(shù)(ε)變化的測(cè)試。
◎ 調(diào)諧回路殘余電感值低至8nH,保證100MHz的(tanδ)和(ε)的誤差較小。
◎ 特制LCD屏菜單式顯示多參數(shù):Q值,測(cè)試頻率,調(diào)諧狀態(tài)等。
◎ Q值量程自動(dòng)/手動(dòng)量程控制。
◎ DPLL合成發(fā)生1kHz~60MHz, 50kHz~160MHz測(cè)試信號(hào)。獨(dú)立信號(hào) 源輸出口,所以本機(jī)又是一臺(tái)合成信號(hào)源。
◎ 測(cè)試裝置符合國(guó)標(biāo)GB/T 1409-2006,美標(biāo)ASTM D150以及IEC60250規(guī)范要求。
電感器:
按測(cè)試頻率要求,需要配置不同量的電感器。
例如:在1MHz測(cè)試頻率時(shí),要配250μH電感器,在50MHz測(cè)試頻率時(shí),要配0.1μH電感器等。
高頻介質(zhì)樣品(選購(gòu)件):
在現(xiàn)行高頻介質(zhì)材料檢定系統(tǒng)中,檢定部門(mén)為高頻介質(zhì)損耗測(cè)量?jī)x提供的測(cè)量標(biāo)準(zhǔn)是高頻標(biāo)準(zhǔn)介質(zhì)樣品。
該樣品由人工藍(lán)寶石,石英玻璃,氧化鋁陶瓷,聚四氟乙烯,環(huán)氧板等材料做成Φ50mm,厚1~2mm測(cè)試樣品。用戶(hù)可按需訂購(gòu),以保證測(cè)試裝置的重復(fù)性和準(zhǔn)確性。
工作頻率范圍是10kHz~120MHz,它能完成工作頻率內(nèi)材料的高頻介質(zhì)損耗角(tanδ)和介電常數(shù)(ε)變化的測(cè)試。
本儀器中測(cè)試裝置是由平板電容器和測(cè)微圓筒線性電容器組成,平板電容器一般用來(lái)夾被測(cè)樣品,配用Q表作為指示儀器。
絕緣材料的損耗角正切值是通過(guò)被測(cè)樣品放入平板電容器和不放樣品的Q值變化和厚度的刻度讀數(shù)通過(guò)公式計(jì)算得到。
同樣,由測(cè)微圓筒線性電容器的電容量讀數(shù)變化,通過(guò)公式計(jì)算得到介電常數(shù)。
主要技術(shù)指標(biāo):
2.1 tanδ和ε性能:
2.1.1 固體絕緣材料測(cè)試頻率10kHz~120MHz的tanδ和ε變化的測(cè)試。
2.1.2 tanδ和ε測(cè)量范圍:
tanδ:0.1~0.00005,ε:1~50
2.1.3 tanδ和ε測(cè)量精度(1MHz):
tanδ:±5%±0.00005,ε:±2%
工作頻率范圍:50kHz~50MHz 四位數(shù)顯,壓控振蕩器
Q值測(cè)量范圍:1~1000三位數(shù)顯,±1Q分辨率
可調(diào)電容范圍:40~500 pF ΔC±3pF
電容測(cè)量誤差:±1%±1pF
Q表殘余電感值:約20nH
裝置:
2.3.1 平板電容器極片尺寸::Φ38mm和Φ50mm二種.
2.3.2 平板電容器間距可調(diào)范圍和分辨率:0~8mm, ±0.01mm
2.3.3 圓筒電容器線性: 0.33 pF /mm±0.05 pF,
2.3.4 圓筒電容器可調(diào)范圍:±12.5mm(±4.2pF)
2.3.5 裝置插頭間距:25mm±0.1mm
2.3.6 裝置損耗角正切值:≤2.5×10-4
北廣電性能及橡膠塑料常用儀器
萬(wàn)能材料試驗(yàn)機(jī)(電子萬(wàn)能,金屬材料,非金屬材料,管材,高低溫,液壓伺服萬(wàn)能試驗(yàn)機(jī))
電壓擊穿試驗(yàn)儀(介電擊穿強(qiáng)度,固體絕緣材料電氣介電強(qiáng)度試驗(yàn)機(jī))
體積表面電阻率測(cè)定儀(可測(cè)試固體液體膏體粉末材料)
碳素材料電阻率測(cè)試儀
電線電纜導(dǎo)體半導(dǎo)體材料電阻率測(cè)試儀
橡膠塑料滑動(dòng)摩擦試驗(yàn)機(jī)(國(guó)標(biāo),非國(guó)標(biāo),可定制)
介電常數(shù)介質(zhì)損耗測(cè)試儀(可測(cè)試固體液體)
學(xué)校介電常數(shù)介質(zhì)損耗測(cè)試儀
高頻介電常數(shù)介質(zhì)損耗測(cè)試儀
工頻介電常數(shù)介質(zhì)損耗測(cè)試儀
絕緣材料耐電弧性能試驗(yàn)儀
液顯熱變形維卡軟化點(diǎn)溫度測(cè)定儀
計(jì)算機(jī)控制熱變形維卡溫度試驗(yàn)機(jī)
塑料球壓痕硬度計(jì)
熔體流動(dòng)速率測(cè)定儀/熔融指數(shù)儀
計(jì)算機(jī)控制馬丁耐熱試驗(yàn)儀
產(chǎn)品保修售后服務(wù)承諾:
一、安裝調(diào)試:協(xié)助試驗(yàn)機(jī)的安裝,負(fù)責(zé)試驗(yàn)機(jī)的運(yùn)輸、調(diào)試。
二、驗(yàn)收標(biāo)準(zhǔn):試驗(yàn)機(jī)按訂貨技術(shù)附件進(jìn)行驗(yàn)收。終驗(yàn)收在買(mǎi)方進(jìn)行,對(duì)用戶(hù)提供的試樣進(jìn)行試驗(yàn),并提供測(cè)試報(bào)告。
三、培訓(xùn):安裝調(diào)試同時(shí),在儀器操作現(xiàn)場(chǎng)一次性免費(fèi)培訓(xùn)操作人員2-3名,該操作人員應(yīng)是由需方選派的長(zhǎng)期穩(wěn)定的員工,培訓(xùn)后能夠?qū)υO(shè)備基本原理、軟件使用、操作、維護(hù)事項(xiàng)理解和應(yīng)用,使人員能夠獨(dú)立操作設(shè)備對(duì)樣品進(jìn)行檢測(cè)、分析,同時(shí)能進(jìn)行基本的維護(hù)。
四、軟件升級(jí):終生免費(fèi)提供新版本控制軟件。
五、保修:
1、設(shè)備保修兩年,終身售后服務(wù),一年內(nèi)非人為損壞的零部件免費(fèi)更換,保修期內(nèi)接到用戶(hù)邀請(qǐng)后,zui遲響應(yīng)時(shí)間為2小時(shí)內(nèi),在與用戶(hù)確認(rèn)故障后,我公司會(huì)在48小時(shí)內(nèi)派工程師到達(dá)現(xiàn)場(chǎng)進(jìn)行免費(fèi)服務(wù),盡快查清故障所在位置和故障原因,并向用戶(hù)及時(shí)報(bào)告故障的原因和排除辦法。
2、保修期內(nèi)人為損壞的零部件按采購(gòu)(加工)價(jià)格收費(fèi)更換。
3、保修期外繼續(xù)為用戶(hù)提供優(yōu)質(zhì)技術(shù)服務(wù),在接到用戶(hù)維修邀請(qǐng)后3天內(nèi)派工程師到達(dá)用戶(hù)現(xiàn)場(chǎng)進(jìn)行維修。并享有優(yōu)惠購(gòu)買(mǎi)零配件的待遇?!?/span>
4、傳感器過(guò)載及整機(jī)電路超壓損壞不在保修范圍內(nèi)。
六、售后管理:
我公司實(shí)現(xiàn)計(jì)算機(jī)化管理,實(shí)行客戶(hù)定期回訪制度,定期復(fù)查設(shè)備的工作情況,定期指導(dǎo)用戶(hù)對(duì)設(shè)備進(jìn)行保養(yǎng)和檢測(cè),以便設(shè)備正常運(yùn)轉(zhuǎn),跟蹤客戶(hù)的設(shè)備使用情況,以便及時(shí)對(duì)設(shè)備進(jìn)行維護(hù)
The working characteristics of dielectric constant and dielectric loss detector
1.Q measurement
A.Q range: 2 ~ 1023;
B.Q range profile: 30, 100, 300, 1000, automatic shift or manual shift;
C. nominal error
A
C
Range of frequency
25kHz ~ 10MHz
100kHz ~ 10MHz
Inherent error
Full scale value is less than or equal to 5% + 2%
Full scale value is less than or equal to 5% + 2%
Working error
Full scale value is less than or equal to 7% + 2%
Full scale value is less than or equal to 7% + 2%
Range of frequency
10MHz ~ 60MHz
10MHz ~ 160MHz
Inherent error
Full scale value is less than or equal to 6% + 2%
Full scale value is less than or equal to 6% + 2%
Working error
Full scale value is less than or equal to 8% + 2%
Full scale value is less than or equal to 8% + 2%
2 inductance measurement range
A
C
14.5nH ~ 8.14H
4.5nH ~ 140mH
3 capacitance measurement
A
C
Direct measurement range
1 ~ 460p
1 ~ 205p
Main capacitance range
40 ~ 500pF
18 ~ 220pF
Accuracy
150pF + 1.5pF;
150pF 1%
150pF + 1.5pF
150pF 1%
Note: the method of measuring the capacitance of the capacitance measuring range is greater than the direct measurement range.
4 signal source frequency coverage
A
C
Range of frequency
10kHz ~ 60MHz
0.1 ~ 160MHz
CH1
10 ~ 99.9999kHz
0.1 ~ 0.999999MHz
CH2
100 ~ 999.999kHz
1 ~ 9.99999MHz
CH3
1 ~ 9.99999MHz
10 ~ 99.9999MHz
CH4
10 ~ 60MHz
100 ~ 160MHz
Frequency indicating error
3 x 10-5 1 words
5.ualified preset function: preset range: 5 ~ 1000
6.Q normal working condition
A. environment temperature: 0 C ~ +40;
B. relative humidity: <80%;
C. power supply: 220V + 22V, 50Hz + 2.5Hz.
7 other
A. power consumption: about 25W;
B. net weight: About 7kg;
C. appearance size: (wide x x x x x x 280) mm:380 x 132.
The attention of the dielectric constant and the dielectric loss meter
1, the test process can not let the unrelated persons close, because this test instrument can produce a higher voltage, without the trained personnel can not use the equipment. When the test must have the guardian, not single use. In case of accident..
2, a long time without the use of equipment, in the re-use, the first instrument no-load pressure once, that the high-voltage electrode wiring from the pressure ball. Check the computer test interface to see if the high voltage is normal..
3, the accident occurred in the test to cut off the power, the problem can continue to test the problem.
4, the device is placed smoothly, the ground to strengthen the ground. It is best to cement the ground to avoid resonance.
5, the equipment in the use of the housing to protect the ground, the equipment casing to earth, to protect the operator and equipment operation safety.
6, after the use of the device, to turn off the system parts of the power, not charged plug power line.
7, according to the power supply voltage access equipment. Make sure the circuit is correct. Otherwise damage equipment.
8, the instrument should be placed indoors, laboratory should be clean, dry, corrosive media, non personnel do not arbitrarily operation.
9, don't let cable equipment encountered sharp edges, so as not to cut the cable insulation; don't let cable in under heavy pressure, to avoid pressure broken cable caused by fire; don't cable pull objects or objects tied with a cable, so as not to pull off the cable so that the device is not functioning properly.
10, do not let the equipment encounter water splash, corrosive gas, combustible gas and combustible material. If you don't avoid it, possibly fire..
11, devices, to cut off the power supply equipment, is to unplug the plug from the socket. No equipment or equipment moving down tilt angle of 45 degrees or above.
12, do not plug the power plug in the device when the device is running.
The characteristics of dielectric constant and dielectric loss detector:
Automatic Q \ \ the company's innovative value technology, the measuring resolution of Q to 0.1Q, the resolution to 0.00005 tan.
Can the solid insulating materials in the dielectric loss angle of 10kHz ~ 120MHz (tan delta) and Permittivity (epsilon) change test.
The tuning circuit of residual low inductance to guarantee 8nH, 100MHz (Tan d) and (E) the error is small.
The special multi parameter LCD screen menu display: Q value, frequency tuning, etc..
The Q value range automatic / manual range control.
The synthesis of DPLL 1kHz ~ 60MHz, 50kHz ~ 160MHz test signal. Independent signal source output port, so this machine is a synthetic signal source.
The test device complies with GB/T 1409-2006, ASTM D150 and IEC60250 American Standard specifications.
Dielectric constant and dielectric loss detector inductors:
According to the test frequency requirements, the need to configure the amount of inductors.
For example, when the frequency of the 1MHz test, with 250 H inductor, at the 50MHz test frequency, with 0.1 H inductor, etc..
High frequency medium sample (optional parts):
In the current high - frequency dielectric material verification system, the calibration department is the high - frequency dielectric loss meter and the measurement standard is the high - frequency standard medium sample.
The sample by artificial sapphire, quartz glass, alumina ceramics, PTFE, epoxy boards, and other materials made with diameter of 50mm, thickness 1 ~ 2mm test samples. Users can order according to the need to ensure the repeatability and accuracy of the testing device.
Range of working frequency is 10kHz ~ 120mhz, it can complete test material in the working frequency of high frequency dielectric loss angle (tan delta) and dielectric permittivity (epsilon) changes.
The instrument in the test apparatus is composed of plate capacitor and measuring cylinder linear capacitor and a parallel plate capacitor is usually used to quilt sample, equipped with the Q table as indicating instrument.
Insulating material loss angle tangent value is through the sample into the panel capacitor and not setting out the Q value of the changes in the thickness and the scale reading calculated by the formula.
Similarly, the cylindrical linear electric micrometer